More types of mobile phones, and the structure can be divided according to speed and low-speed high-speed mobile phones, high-speed mobile dental handpiece using high pressure air driven turbine handpiece for micro turbine speed can be up to 300,000 to 500,000 r / min, bur cutting speed can be up to 15m / s, while the low-speed mobile dental handpiece because it is gear, speed can be transferred per minute for thousands of 30000 rpm.
2013年8月15日星期四
diamond burs
Bur is dentist consumables used appliances, is a very small needle, the needle from the needle and the needle handle composition, can be inserted into high-speed mobile phone use, to help
Help dentists open cavities, dental scaler repair teeth. If dentists metaphor for handheld rig with a cell phone, then the equivalent of bur drill rig.
Bur, currently divided into tungsten steel burs and diamond burs. Carbide burs which are more commonly used in foreign and domestic, dentists used primarily for diamond bur .
Emery car attached needle Ministry tiny diamond drill peripheral particles, these diamond particles go through the complex, demagnetization, rounded, purification treatment, the sharpness and resistance
Grinding degree with outstanding performance. Diamond bur during use, emery will gradually fall, usually in the diamond drop half the time, the life of this root bur
To an end.
Classification of diamond burs
Classified by function: High-speed, low-speed (16,30,45 jrpm)
Classification by length: standard, short, ultra short-throw (17-26mm)
Classification by weight: coarse, standard, fine, superfine
Grouped by usage: repair abutment preparation, preparation hole type, etc.
By morphological classification: various forms
Emery by category Category: natural and artificial
By Life Category: Disposable, repeatability
The composition of diamond burs
Magic gravel, adhesives, stainless steel handle
The role of the adhesive
1, emery and the dental Endo Box substrate so firmly bonded together.
2, high-quality adhesive surface ensures bur rotating at high speed does not cause turbidity.
3, natural emery and substrate binding is all kinds of abrasive bonded to the substrate, the most difficult and most technical content.
Diamond burs - used several diamond bur
1, the Japanese Shofu
2, the German DFS
3, the Swiss Duracell
4, the United States KEER
5, Japan, Manila
what determines the life of diamond burs
Bur, especially diamond bur dental doctor is the most frequently used tools. But because of its relatively low cost, many doctors ignore its maintenance and
Maintenance. And there are many doctors that: "I use *** brand bur, used once and throw away!" The doctor said these words to express the meaning of non-
Often clear that this car has Gutta Percha Points been sterilized needle after grinding cutting ability decreased significantly. What causes this phenomenon it?
Are summarized as follows:
First, the reasons for sterilization
There are many doctors use a 2% glutaraldehyde for disinfection, you know, glutaraldehyde has some corrosion on the metal, and the disinfection process soaking time than
Long. So there are many doctors complain especially tungsten steel bur bur rust problems.
For steel and tungsten carbide bur is recommended that:
1, autoclavable, for disinfection prior to remain in the blood stains on the bur and tooth tissue debris and timely water rinse, if necessary, use a brush to clean.
2, good quality and bad bur bur sterilized separately to avoid mutual influence
Second, the high-speed impact of the turbine water spray
Because dental chair using a certain time produced a change or anthropogenic causes water becomes smaller. At this point bur rotating at high speed process can not be effectively cooled, would produce a certain
Was loss.
Recommends regular inspection of water meets 50 ml / min standard
Third, the choice of bur
You doctor should pay attention to the difference in the consumer's selection of diamond bur is synthetic or natural diamond emery. The difference between them is that the former will
Decreased cutting force there dental scaler grinding abrasion resistance of the latter is relatively long.
The above is a synthetic diamond micro-graph, edges relatively simple, polished edges after cutting ability has decreased significantly. Synthetic diamond bur lower cost in the market
The sales price is relatively uniform, no matter what form the thickness of both a price.
2013年8月14日星期三
how to choose the dental chair
First, the basic method of selection of the dental chair
1: dental chair price is a primary consideration. How to spend less and it can guarantee the quality of the dental chair?
First, the volume of business you expect to see much, if you expect the volume of business is very small, the budget is not large, it is recommended that you buy a pneumatic hydraulic type dental chair,
This dental chair prices low, but denture teeth poor durability. If you are a business volume also dental clinic, or the main consideration electric dental chair.
What is a pneumatic hydraulic type dental chair it? Pneumatic dental chair refers to gas film control handset operation, the main features are disc foot switch to control the chair position with hydraulic
Exercise, hydraulic pumps and hydraulic pipes. Why is it less durable, mainly with the electronically controlled motor-type dental unit of comparison. Electrically controlled solenoid means
Valve control handset operation, the main feature is a versatile electric foot switch or foot switch, the motor is a motor control chair position movements.
European production of dental chair chair position is mainly motor control action, open the seat backrest can see the control action of the small motor. So when do you expect the volume of business
Large, as far as possible choose this dental chair, it is more durable, but the price is relatively high.
Of course, now more and more dental clinics are used as the main electric dental chair dental equipment.
2: After selecting the dental chair models, depending on configuration suitable to themselves. If you are an oral physician, and less than strong suction, you can dispense with strong suction (if
Strong suction is not optional but standard time). In fact, the two phones is a luxury configuration, you can view a decrease in demand.
3: identification of dental dental scaler treatment machine quality quality, but also observed from the following aspects.
First, look at the appearance of the machine, to see whether the combination of tight junction shell, if the gap is large, show quality, but off.
Then take a look at the finish of metal parts and machining precision metal parts here mainly refers to three with a gun and a cell phone sleeve, if they are very rough, Table
Ming poor quality. Finally, open the shell observed cardiac chair position control: motor or pump.
Second, the method of selection of professional dental chairs
Able for the above judgment to show that you have mastered the basic method of selecting the dental chair. Here is more from the perspective of how to choose a professional dental chair.
2013年8月7日星期三
medical portable X-ray machine
Small size, light weight, easy diagnosis; ray dose is low, safe and reliable protection, ensure that physicians health; high sensitivity, high spatial resolution image intensifier. Give you a new
Visual effects;; film can be equipped with systems and video surveillance system.
Applications: Is the hospital orthopedic surgery especially indispensable tool for doctors, doors, emergency room visits, rounds and surgical scene repeated X-ray examination of the extremities
Closed reduction of fracture, fixation, needle, foreign body, especially for the installation noose intramedullary nail or supporting the use of external fixation works best when newborn babies and young children
X-ray examination and gynecological Dental Vacuum Former IUD technical parameters
A field of view: Φ50mm; 2, Resolution: 36Ip/cm; 3, the output screen brightness:> 6cd/cm2;
4, the maximum spacing: 300mm; 5, the tube voltage :60-75kv; 6, tube target flow :0.15-0 .3 mA;
7, Contrast Ratio: 4%; 8, gray: 7; 9, the leakage radiation: <5mR / h;
10, Weight: 5kg; 11, Power: 50W; 12, power supply: 220VAC.
Fourth, the method of operation
1, remove the host from the box, the power output of the power supply box plug socket on the machine;
2, the mains power plug connected to 220V power supply, power supply, green LED should light, and then put the observed object detection range (as close to the imager)
, Hold a finger on the host switch dental scaler (foot switch can also be made) pressing the switch button;
3, the instrument automatically shut down after work one minute, stop for a few seconds, you can boot again, repeatedly. Can be viewed directly on the display. .
4, observed after turning off the power switch, unplug the power cord, and then unplug the machine power cord, press the screen cover, the machine, power cords into the chassis
In;
Visual effects;; film can be equipped with systems and video surveillance system.
Applications: Is the hospital orthopedic surgery especially indispensable tool for doctors, doors, emergency room visits, rounds and surgical scene repeated X-ray examination of the extremities
Closed reduction of fracture, fixation, needle, foreign body, especially for the installation noose intramedullary nail or supporting the use of external fixation works best when newborn babies and young children
X-ray examination and gynecological Dental Vacuum Former IUD technical parameters
A field of view: Φ50mm; 2, Resolution: 36Ip/cm; 3, the output screen brightness:> 6cd/cm2;
4, the maximum spacing: 300mm; 5, the tube voltage :60-75kv; 6, tube target flow :0.15-0 .3 mA;
7, Contrast Ratio: 4%; 8, gray: 7; 9, the leakage radiation: <5mR / h;
10, Weight: 5kg; 11, Power: 50W; 12, power supply: 220VAC.
Fourth, the method of operation
1, remove the host from the box, the power output of the power supply box plug socket on the machine;
2, the mains power plug connected to 220V power supply, power supply, green LED should light, and then put the observed object detection range (as close to the imager)
, Hold a finger on the host switch dental scaler (foot switch can also be made) pressing the switch button;
3, the instrument automatically shut down after work one minute, stop for a few seconds, you can boot again, repeatedly. Can be viewed directly on the display. .
4, observed after turning off the power switch, unplug the power cord, and then unplug the machine power cord, press the screen cover, the machine, power cords into the chassis
In;
2013年7月31日星期三
the dental drill
the dental drill
Bur John Greenwood was the first U.S. president George Washington's dentist. Washington made his dentures and used by his mother's spinning machine to change
Made a wonderful device for the Washington dental drill.
Greenwood pedal pedal driven dental drill. However, his device does not promote the use of dental doctors still hand turning the handle to drive the dental drill. Anesthesia
Drugs used first by the fact dental scaler that the dentist, indicating early dental drill and make painful extractions.
In 1858, George Harrington invented the first motor-driven dental drill. Dental drill attached to the dentist's hand holding a watch-like device. Other
The motor-driven `have invented dental drill. Some are electric, some pneumatic. Today's dental drill speed is dental canal very fast, so you need to use ice water jet to
Prevent the drill bit temperature is too high. The application of local anesthetic so that the patient does not feel pain almost.
Bur John Greenwood was the first U.S. president George Washington's dentist. Washington made his dentures and used by his mother's spinning machine to change
Made a wonderful device for the Washington dental drill.
Greenwood pedal pedal driven dental drill. However, his device does not promote the use of dental doctors still hand turning the handle to drive the dental drill. Anesthesia
Drugs used first by the fact dental scaler that the dentist, indicating early dental drill and make painful extractions.
In 1858, George Harrington invented the first motor-driven dental drill. Dental drill attached to the dentist's hand holding a watch-like device. Other
The motor-driven `have invented dental drill. Some are electric, some pneumatic. Today's dental drill speed is dental canal very fast, so you need to use ice water jet to
Prevent the drill bit temperature is too high. The application of local anesthetic so that the patient does not feel pain almost.
2013年7月25日星期四
teeth correction stunned important to you
Many types of dental abnormalities or defects, some small, there is a simple, but also complex.
Tooth color abnormalities such as tetracycline, dental fluorosis, discolored teeth and so on. Alignment of teeth abnormalities such as crowding dentition sparse, misplaced teeth and so on. Dental abnormalities, such as twist angle
Turn teeth, tilt teeth and so on.
For example there is a large jaw deformities, including the mandibular prognathism or mandibular prognathism, anti together to open and close, a small jaw and so on. The teeth dental instruments or defects in shape and size, there are teeth
Abnormalities, such as too small teeth, conical teeth, enamel hypoplasia, shaped teeth, a variety of causes crown defect or crack.
Anterior dentition defects such as missing posterior teeth loss and so on. We can say that the above conditions are in need of treatment. Because most of them will not only affect the appearance, but also affect the positive
Normal functioning. Recommended reading: dental scaler malocclusion orthodontic best time
After treatment, teeth or denture to restore form, function and aesthetics are the general principles of dental treatment, cosmetic dentistry is not so simple sense of landscaping, it taking into account the
Or through the restoration of physiological function.
In dental practice includes both cosmetic factors or dental treatment itself objectively also played the role of beauty. Only targeted have to choose their own
Orthodontics is the most important.
订阅:
博文 (Atom)